Co-development
Airborne low-frequency monitoring
Measure local air-pressure changes near a known machine and assess whether they add useful information.
Jump to the test planPublished research
Independent studies · Free-to-read full text
-
Performance comparison of measurement microphones and microbarometers for sound pressure measurements near wind power plants
Rust & Koch · Journal of Low Frequency Noise, Vibration and Active Control · 2024 · 10.1177/14613484231200852
Field and wind-tunnel measurements showed that wind-induced pressure fluctuations can dominate infrasound recordings.
-
Non-Contact Bearing Fault Diagnostics: Experimental Investigation of Microphones Position and Distance
Voltolini et al. · Applied Sciences · 2026 · 10.3390/app16083670
Microphone placement mattered in bench tests. The reported fault detection relied on high-frequency envelope analysis, and low-frequency turbulence appeared in both healthy and faulty records.
Technical feasibility
A calibrated pressure channel can measure low-frequency signals. Airflow and local disturbances can dominate the recording. The first use case is one machine with a known operating state and an existing vibration reference.
Proposed first test
Record synchronized air pressure and vibration at one guarded machine. Test state detection on held-out sessions and compare combined sensing with the vibration-only baseline.
Proposed pass criterion
Target at least 90% detection of the defined state with at most 5% false alerts, and require added value over vibration alone at a matched false-alert rate.
These are research targets. This brief reports independent findings and a proposed test plan for SpectraCortex.